Healthtech technical due diligence: a checklist
Technical due diligence tests whether a company's software, data handling and team can support the plan you are investing in. In healthtech it also tests whether patient data is handled under documented safeguards, and whether EHR access the product depends on will survive a change of ownership. Ask for evidence, not descriptions.
Key takeaways
- Technical DD covers architecture, code quality, security, data flows, integrations, team, cost, scalability, licences and AI usage.
- In healthtech, the decisive questions are about PHI: where it goes, which vendors see it, and what the HIPAA program can prove.
- EHR integrations often rest on access granted by customers or vendor programs. Check who holds it and whether it transfers.
- Single-engineer knowledge is a risk you can measure. Ask a second engineer to build and explain the system.
- The output is a ranked list of findings with remediation cost, not a pass or fail.
What technical due diligence examines
Architecture
Ask for one current diagram showing systems, data stores and external services. Then ask an engineer to trace a single test record through it. Gaps between the diagram and the trace are findings.
Code quality and delivery
Look at test coverage on critical paths, the CI/CD pipeline, release frequency and how a release is rolled back. Read a sample of recent pull requests. Review quality shows up there faster than in metrics.
Security and the HIPAA program
The Security Rule requires an accurate and thorough risk analysis and risk management (45 CFR 164.308). Ask for the current risk analysis and its date. Ask what changed because of it.
Technical safeguards in 45 CFR 164.312 cover access control, audit controls, integrity, authentication and transmission security. Ask how each is implemented, and see it working.
Required HIPAA documentation must be retained for six years from creation or last effective date (45 CFR 164.316). Missing history is a finding, not a formality.
PHI data flows
Map every place patient data lands: databases, file storage, logs, analytics, support tools, email, backups and developer machines. Logs and support tools are where PHI most often turns up unplanned.
BAAs and the vendor list
A covered entity may let a business associate handle ePHI only with "satisfactory assurances" that it will safeguard it (45 CFR 164.308(b)). Business associates need the same assurances from their subcontractors (45 CFR 164.502(e)).
Request the full vendor list. Match every vendor that sees PHI to a signed business associate arrangement. Unmatched vendors are a finding.
EHR integrations and access dependencies
For each integration, record the access path: open developer program, marketplace or partner program, customer-sponsored enterprise access, or a fallback such as a vendor-built interface or practice export. Our EMR integration guide describes these paths.
Then ask who holds the access. A partner agreement, an app registration and a customer's activation are separate things. Check the terms on transfer and change of control with counsel.
Team and bus factor
List who can deploy, who holds admin rights, and who understands each critical system. If one name appears on every line, that is the bus factor. Ask whether contractors or an agency hold any of it.
Infrastructure cost
Get the last several months of cloud bills by service. Compare cost to usage. Ask what drives cost growth and what happens to it at ten times current load.
Scalability
Ask for load test results or production metrics on the busiest workflow. Identify the component that fails first and the plan for it.
Licences and open source
Request a software bill of materials or dependency inventory. Flag copyleft licences in distributed code, unmaintained packages and commercial components without a transferable licence. Counsel interprets the rights. Engineering supplies the inventory.
AI and ML usage
List every model or AI service in the product and the data each receives. If PHI reaches an external model, it needs a business associate arrangement like any other vendor. Ask what rights the company has to training data and model outputs, and whether customer contracts allow that use.
Technical due diligence checklist
| Area | Evidence to request | How to verify | Red flag |
|---|---|---|---|
| Architecture | Current system diagram | Trace one test record end to end | Diagram and trace disagree |
| Code and delivery | Repo access, CI/CD config | Second engineer builds and deploys | Build needs one person's laptop |
| HIPAA program | Risk analysis, policies, dates | Ask what changed after the last analysis | No risk analysis on file |
| Technical safeguards | Access, audit, encryption design | Demonstrate an audit log query | No record of who viewed what |
| PHI data flows | Data flow inventory | Search logs and support tools for PHI | PHI in logs or tickets |
| Vendors | Vendor list with BAA status | Match each PHI vendor to a BAA | PHI in a tool without a BAA |
| EHR integrations | Access path per EHR | Confirm who holds each agreement | Access tied to a customer or individual |
| Team | Roles, admin rights, deploy rights | Interview more than one engineer | One person holds every key |
| Cost | Cloud bills by service | Compare to usage | Unexplained growth |
| Scalability | Load or production metrics | Identify first bottleneck | No data on peak load |
| Licences | Dependency inventory | Licence scan reviewed by counsel | Untracked copyleft or commercial code |
| AI/ML | Model list, data inputs, contracts | Trace PHI into each model | PHI sent to a model without terms |
Healthtech red flags
Integration built on access the company can't keep. The integration runs on a customer's credentials, a former employee's developer account, or an arrangement that ends on change of control. The product works today and may not after closing.
PHI in tools without BAAs. Patient data in a logging service, chat tool, analytics platform or AI API with no business associate arrangement in place.
No audit logs. The audit controls standard requires mechanisms that "record and examine activity" in systems containing ePHI. If the company cannot show who accessed a record, it cannot investigate an incident.
Single-engineer knowledge. One person deploys, holds the cloud root account and is the only one who understands the integration layer. Ask that person's colleagues to explain the system without them.
Risk analysis that never changed anything. A document exists, but no control, ticket or decision traces back to it.
What you should receive
- A findings register ranked by severity, each with evidence and an owner.
- A PHI data flow map and a vendor list with BAA status.
- An integration register: access path, holder and transfer risk per EHR.
- A team and access map, including the bus factor.
- A remediation plan separating pre-close items from post-close work, with estimates where the evidence supports them.
If the company is preparing for a raise rather than being assessed, the same evidence should already exist. Our guide to a healthtech technical handover before fundraising covers how to assemble it.
How BitLab does it
BitLab's 48-hour codebase and team audit is an independent review for healthtech companies. Repo access is under NDA. Our CTO and senior engineers review architecture, compliance posture, tech debt and team structure.
The audit report includes a prioritized 90-day roadmap. Every finding is walked through on a strategy call afterwards. The written report is yours to keep.
It starts with a free 30-minute discovery call, where we confirm fit, scope and access requirements. Founders can bring a cofounder, CTO or investor to that call.
We also cover HIPAA engineering in HIPAA compliance in healthtech software development, and ongoing technical leadership through our fractional CTO for healthtech service.
FAQ
What is technical due diligence?
An independent assessment of a company's software, infrastructure, data handling and engineering team before an investment, acquisition or board decision. It identifies risks and the cost of fixing them.
What should a technical due diligence checklist include?
Architecture, code quality, security program evidence, data flows, vendors and contracts, integrations, team and access, infrastructure cost, scalability, licences and AI usage. In healthtech, add PHI mapping, BAA coverage and EHR access dependencies.
How is healthtech due diligence different from software due diligence?
It adds HIPAA program evidence, PHI data flows, business associate coverage and EHR integration access. Those can block or reprice a deal even when the code is sound.
What is the most common healthtech red flag?
PHI appearing in tools without a business associate arrangement, such as logs, support tools or AI services. The second is integration access held by a customer or one individual.
Does technical due diligence replace legal review?
No. Engineering supplies the inventory and evidence: vendors, licences, access agreements. Counsel interprets the contracts and rights.
How long does technical due diligence take?
It depends on scope and on how quickly the company provides access and evidence. A focused review moves faster when the inventories already exist.
Sources
The audit is free. Another quarter of guessing is not.
Book the Free 48-Hour Audit